SWTC SWC · Kenya

Reusing an old UL 60950-1 report led to an entire batch being returned by the North American customer

The customer used a 2018 UL 60950-1 report to respond to a new order in 2024.

UL 60950-1 has been withdrawn, and the customer's compliance department requires a UL 62368-1 report, so the entire shipment was put on hold and not accepted.

Conduct a standard gap assessment: differences between 62368-1 and 60950-1 in energy source classification, fire enclosure, and temperature rise criteria; supplement ES1/ES2/PS1/PS2 energy source determination and fire enclosure assessment; retest key items and issue a UL 62368-1 report; simultaneously update the standard references on the nameplate and in the instruction manual.

Complete the standard upgrade in 3 weeks and release the goods.

Standard generation changes are more fatal than "expired reports," and a standard version monitoring mechanism needs to be established. UL 60950-1 has been replaced by UL 62368-1, and new projects should no longer reference it. Reviews by customer compliance departments are often stricter than regulatory reviews, so preparations should be made according to their checklist.

Reversing that order usually costs an extra round of sample and an extra round of testing.

Prepared by the Shuwang certification engineering team from live project records.

Service boundary: Shuwang Certification Platform is an export certification solution provider. It does not perform testing and is not a certification body. Testing described on this page is carried out by partner laboratories accredited to CNAS/CMA or ISO/IEC 17025; certificates are issued by EU Notified Bodies or by the authorised bodies of the destination country. Lead times and cost ranges are public industry references and depend on engineer assessment and body scheduling.

Next step

Send your product and destination, and an engineer will come back with the applicable scheme.

Send to an engineer